60 amp is the high value of current, irrespective of whether it is used to operate 12 12-volt or 24-volt electrical telling motor or used in 120/230 volts electrical systems to power homes, RVs, etc. For measuring the thickness of wire there are different parameters used. The accurate size of the wire for the breaker connected with a 60 amp capacity lies between 6 and 4 AWG. Let’s start with 60 Amp Wire Size – How to Calculate Proper Wire Gauge
What Is Ampacity
Ampacity is the highest current that can flow through certain wires at given voltage losses and temperatures. The wire length should not used to find the wire size. The large gap between the panel and subpanel, or load connected from the subpanel needed larger size conductors. To reduce the larger voltage loss must follow the ampacity value seriously and use wire size accurately.
How to Determine Wire Size
The ampacity of the wire must not for main factor for selecting wire size for a 60 amp breaker, we will use an 80% breaker rating rule to find wire size
What is 80% Breaker Rating Rule?
According to the NEC code, the 80% breaker rating rule is used to find the size of different wires. These details are used to ensure electrical safety. Supposedly we have to find the value of the wire size for the 60 amp breaker. it can be from 60 amp hot tub wire to 60 amp wire service. The wire size needed for 60 amp is 80% of the required wire size. it means wire can handle 48 amps for a 60 amp breaker. SO find value.
60 amps x 80%= 48 amps Wire Size
The 5 AWg wire is a size that can handle more than 75 amperes. It is also used for that 4 AWG can handle 85 ampers, it is good for accurately wire 60 amp breaker.
Wire Size for 60 Ampere Breaker
For 60 amper breakers normally the wire size used is from 6AWg to 4 AWG. All house wires come with a rating of about 600 volts, so just amper effects for finding wire gauge. So wire size of 60amp 220 volts is from 6 to 4 AWG. However some engineers say that 4AWg wire is installed for the 60 amp breaker panel. because 60 amp subpanel wire size is standard for 60 amp subpanels. Since 4 AWG holes larger ampere than 6 AWG wires. 4 AWg copper cable handles 7o amps and 6 AWg copper wire handles 55 amps. Here is the chart showing the ampere capacity of different AWG cables. This table is for copper wires
14-gauge wire | 15 amps |
12-gauge wire | 20 amps |
10-gauge wire | 30 amps |
8-gauge wire | 40 amps |
6-gauge wire | 55 amps |
4-gauge wire | 70 amps |
3-gauge wire | 85 amps |
2-gauge wire | 95 amps |
Why Size Wire is Important for Breakers
Wire size is important for breakers due to safety concerns. The total size of the wire defines whether the conductor of the wire handles ampere passing through it. If the wire cannot handle a certain value of amper it will be melted and also burn in some cases, causing a fire that can burn complete home wiring. Due to this reason, we should use accurate wire size and capacity to carry an ampere load. The basic rule is that thick and larger size wire has the ability to handle larger ampere loads since they handle heat generated by current passing through it
Wire Size for a 60-amp Subpanel 50, 100, or 150 Feet Away
For 60 amps, the 6 Gauge wire is best to use for 50 feet. For 100 feet use 4 gauge wire, it also used for 150 feet. in simple words, a 6 gauge wire is used for 60 amp, but the best option is 4 gauge wiring. The length of the wire is an important factor for using a gauge. The wire will resist current flow. Linger wire will have high resistance. For limited voltage losses use wire size that handles handle required distance.
Can 8, 6, 10 Gauge Wire Handle 60 Amps?
60 amp uses 4 gauge wire, some people use 6 gauge wires, But 5 gauge wire is best to use. 8 and 10 gauge wire is also not used.
60 Amps wire size- AWG 4 or AWG 3 wire
To reduce the power losses minimum, for a longer scale, thick wire is used. Many rules and standards are used for measuring wire thickness, best solution is to use ten percent for every 50 feet of wire length. Such as measuring the required ampacity of 50 feet, 100 feet, and 150 feet wires use the default value of 70 amps measured with 80% Rule
50 feet distance wire: Ampacity = 75 Amps x 1.1 = 82.5 Amps
100 feet long wire: Ampacity = 75 Amps x 1.2 = 90 Amps
150 feet long wire: Ampacity = 75 Amps x 1.3 = 97.5 Amps
Read Also:
- 40 Amp Wire Size
- 30 Amp Wire Size
- Wire Gauge For 20 Amp Circuit
- 14/2 vs 14/3 Gauge Cables: What’s the Difference?